Introducing Our State-of-the-art Auto CPAP APAP Machine with Humidifier Expiratory Pressure Relief For Home Use
The Auto CPAP Machine with Heated Humidifier (Model DS-6) is a sophisticated medical device engineered to provide advanced respiratory support for individuals suffering from Obstructive Sleep Apnea (OSA) and Central Sleep Apnea (CSA). Combining cutting-edge technology with user-centric design, it delivers customized and comfortable therapy for improved breathing during sleep.
Specification
Specification | Details |
Description | DS-6 |
Work Mode | CPAP, Auto |
Color | Silver |
Sound | <28 dB |
Screen | 2.8 inch TFT, 320 x 240 |
Pressure Range | 4-20 cmH2O, auto adjustment |
Data Storage | SD Card |
Power Supply | Input 100-240V, 50-60Hz, 1.2A; Output 24V, 2.5A |
DC Voltage | 24VDC, 2.5A |
Over-Temperature Protection | Stop automatically; alarm with 4 times |
Lock Function | Yes |
Screen Auto Sleep | Auto sleep in 15 minutes; press any button to highlight screen |
Ramp Item | 0-60 min adjustable, 1min/Step |
Auto ON/OFF | Yes |
EPR | Yes, 0-3 level |
Auto-Altitude | Yes |
Leak Compensation | Yes |
Awake Detection | Yes |
Breath Event Detection | Yes |
Auto Pressure Titration | Yes |
Water Capacity | 220mL max |
Humidifier Level | Integrated Heated, 0-5 level |
Alert | Power Off ,Mask Off |
Dimensions (cm) | 28.1 x 14.9 x 9.5 (machine); 38.5L x 38.5W x 16H (carton) |
Weight (with humidifier) | 1.6kg (net); 3.9kg (gross weight) |
Work For | CSA, OSA |
Applicable Conditions | Relieve Snoring ,Mild Sleep Apnea |
Experience Elegance in Relief: Your
Auto CPAP APAP Machine with Humidifier Expiratory Pressure Relief For Home Use Solution
Enhanced Features and Benefits:
Advanced Pressure Adjustment
Equipped with Auto-CPAP functionality, the machine adapts in real-time to the user’s breathing patterns, maintaining optimal airway pressure between 4-20 cmH2O.Includes dual pressure settings: a lower baseline to minimize apnea events and a higher level for enhanced respiratory support.
Expiratory Pressure Relief (EPR)
Offers three adjustable levels (0-3) of expiratory pressure relief, ensuring a seamless transition during exhalation for superior comfort.Synchronizes perfectly with the patient’s breathing cycle to enhance therapy efficiency.
Whisper-Quiet Operation
Powered by a high-efficiency, brushless DC motor with noise-canceling technology, the device operates at an ultra-quiet <28 dB, ensuring an undisturbed sleep environment.
Integrated Heated Humidifier
Features a built-in humidification system with adjustable levels (0-5), designed to prevent dryness and irritation by maintaining optimal moisture levels in the airway.The 220 mL capacity water chamber is easy to fill and clean, ensuring hassle-free maintenance.
.
Intelligent Monitoring and Safety
Uses smart sensors to continuously monitor and adjust airflow based on real-time feedback.Includes an auto shutoff system for overheating protection and alerts for system errors, ensuring safe and reliable use.
Ease To Use
The intuitive 2.8-inch TFT display provides clear navigation for adjusting settings and monitoring therapy progress.A compact design measuring 28.1 x 14.9 x 9.5 cm, making it ideal for home or travel use.
Additional Functionalities
Features auto-start/stop, leak compensation, and breath event detection for seamless operation.Includes a ramp-up mode that gradually increases pressure over 1-60 minutes, allowing users to acclimate comfortably.
How to Use the Auto CPAP APAP Machine with Humidifier Expiratory Pressure Relief For Home Use (Model DS-6)
The Auto CPAP machine is designed to provide customizable and efficient therapy for sleep apnea. Follow these step-by-step instructions to operate the device effectively:
Setting Up the Device
- Assemble Components:
- Connect the tubing to the CPAP machine and the mask.
- Attach the humidifier chamber and fill it with distilled water (do not exceed the maximum fill line).
- Connect to Power:
- Plug the power cord into the machine and a suitable wall outlet (AC 100-240V). Ensure the device is stable on a flat surface.
- Turn On the Device:
- Press the power button to activate the machine. The display screen will light up, indicating the machine is ready for use.
Using CPAP Mode
- Access CPAP Mode:
- Navigate to the Work Mode menu and select “CPAP” using the Enter button.
- Set Working Pressure:
- Highlight the “Pressure” option using the Enter button.
- Adjust the working pressure by pressing the Up/Down buttons to select the desired pressure level (range: 4-20 cmH2O). This pressure remains constant throughout therapy.
- Start Therapy:
- Secure the mask on your face, ensuring a comfortable and airtight fit.
- Press the Start button, and the device will begin delivering constant positive airway pressure.
Using Auto CPAP Mode
- Access Auto CPAP Mode:
- Navigate to the Work Mode menu and select “Auto CPAP” using the Enter button.
- Set Pressure Range:
- Highlight the “Pressure” option using the Enter button.
- Adjust the Minimum Pressure and Maximum Pressure settings using the Up/Down buttons. This range determines the automatic adjustment limits (range: 4-20 cmH2O).
- Monitor Therapy:
- The machine will automatically adjust pressure within the specified range based on your breathing patterns throughout the night.
Adjusting Other Settings
- Ramp Function:
- Highlight the “Ramp” option to set the ramp duration (1-60 minutes). This feature gradually increases pressure to the therapeutic level, allowing for a more comfortable start to therapy.
- Expiratory Pressure Relief (EPR):
- Access the EPR settings and choose the desired level (0-3) to reduce pressure during exhalation, enhancing comfort.
- Humidifier Level:
- Adjust the humidification level (0-5) to prevent dryness and irritation. Ensure the water chamber is filled with distilled water before starting therapy.
During Therapy
- Mask Fit Check:
- Verify that the mask is secure and free of leaks. Adjust straps or reposition the mask if necessary.
- Auto On/Off:
- Enable the Auto Start/Stop feature for hands-free operation. The machine will start when you breathe into the mask and stop when the mask is removed.
After Therapy
- Turn Off the Machine:
- Press the power button to turn off the machine. Allow the humidifier chamber to cool before handling.
- Daily Maintenance:
- Empty and clean the humidifier chamber and tubing. Allow them to air dry before reassembly.
By following these steps, users can maximize the comfort and effectiveness of their CPAP therapy. Always refer to the user manual for specific instructions and consult your healthcare provider for personalized settings.
Precautions and Cautions for Using Auto CPAP APAP Machine with Humidifier Expiratory Pressure Relief For Home Use (Model DS-6)
To ensure safe and effective use of the DS-6 Auto CPAP Machine, users must adhere to the following precautions and cautions:
General Safety Precautions
- Medical Supervision: Always use the device under the guidance of a licensed healthcare professional to ensure that settings and therapy parameters are appropriate for your condition.
- Intended Use: This device is designed exclusively for the treatment of sleep apnea and respiratory conditions. Do not use it for other purposes unless advised by a physician.
- Children and Pets: Keep the device out of reach of children and pets to prevent accidental damage or injury.
Setup and Operation
- Electrical Safety:
- Use only the supplied power cord and adapter to avoid electrical hazards.
- Ensure the power source meets the specified voltage requirements (AC 100-240V, 50/60Hz).
- Avoid operating the device near water or in damp environments to prevent electric shock.
- Environment:
- Place the device on a stable, flat surface away from direct sunlight, heat sources, or dusty areas.
- Maintain adequate ventilation around the device to prevent overheating.
- Humidifier Use:
- Always use distilled water in the humidifier chamber to prevent mineral buildup and contamination.
- Do not overfill the water tank, and ensure it is securely attached before operating the device.
- Empty and clean the water chamber daily to avoid bacterial growth.
Device Maintenance
- Regular Cleaning:
- Clean the mask, tubing, and humidifier chamber as instructed in the user manual. Use mild detergent and air-dry completely.
- Do not immerse the main device in water or expose it to cleaning agents.
- Filter Replacement:
- Check the air filter regularly and replace it as needed to ensure optimal airflow and device performance.
- Use only manufacturer-recommended replacement parts.
- Inspection:
- Periodically inspect the device, mask, tubing, and accessories for signs of wear, damage, or leaks.
- Replace worn or damaged components promptly to maintain effective therapy.
During Use
- Monitor for Discomfort:
- If you experience discomfort, skin irritation, or difficulty breathing, stop using the device and consult your healthcare provider.
- Ensure the mask is properly fitted to avoid air leaks, which may compromise therapy effectiveness.
- Avoid Alcohol and Sedatives:
- Refrain from consuming alcohol or sedative medications before using the CPAP device, as they may impair breathing patterns and reduce the efficacy of the therapy.
- Travel Considerations:
- Use a travel case to protect the device when traveling.
- Check the power compatibility for international use and carry an appropriate adapter if needed.
Warnings
- Emergency Use:
- This device is not intended for life-support applications. If an emergency occurs, seek immediate medical assistance.
- Malfunction:
- In case of device malfunction or unusual noise, discontinue use and contact customer support or a certified technician.
- Contraindications:
- Individuals with severe respiratory disorders, recent upper airway surgery, or certain cardiac conditions should consult a physician before using the device.
By following these precautions and cautions, you can maximize the safety, comfort, and effectiveness of your VentMed DS-6 Auto CPAP therapy. For further assistance, refer to the user manual or contact the manufacturer.
Packing List
Device
Travel Bag
Nasal Mask
SD Card
Air Tubing
Instruction Manual
Power Adapter
Water Tank
Filter
FAQ
Our product is built to last, offering dependable performance for a generally trouble-free period of three to five years. Regular maintenance can be conveniently done at home – simply use a cotton bud to clean the air intake and filter to remove dust.